具有比例因子的线性误差校正
来自ArcoWiki
Introduction
In addition to the full 24 parameter volumetric compensation of the CMM, it is possible to apply Scale Factores to correct some residual linear error.
Procedure
The factors shall be add to a figuration file as follow:
- Open the Folder ..\Data with Windows Explorer
- Open the File Machine.ini
- If not present, add in the bottom of the file the following lines:
[SFACTORS] SFX1=1 SFY1=1 SFZ1=1 SFX2=1 SFY2=1 SFZ2=1
- Type, for each axis and for arm, the scale correction to be applied
- Press File -> Save
- Press File -> Exit
Usage Warning
THE CORRECTION OF THE LINEAR ERRORS WITH SCALE FACTOR IT IS NOT RECOMMENDED AND IT IS PREFERABLE TO USE A FULL ERROR MAPPING.
Scale Factor Calculation
Scale factor= nominal length of the gauge / measured length of the block[[en:Correction of Linear Error With Scale Factors]